MF-8-150
|
MF-16-170
|
MF-16-250
|
| Circuit Breaker |
(1) 50 Amps, 3 Pole ** |
(1) 70 Amps, 3 Pole ** |
(2) 50 Amps, 3 Pole ** |
|
Single 8 Zone main frame construction |
Two 8 Zone Main Frames stacked construction |
Two 8 Zone Main Frames stacked construction |
| Max. Amperage |
15 Amps per zone |
| Power |
240 VAC, Single
Phase, 3 Wire (2 AC & 1 Ground), 50-60 Hz. |
| Vital Feature |
Anti-Arching
circuitry |
| Thermocouple |
Type "J" |
| Mold Interface |
Accomplished through dedicated power cord with ground
(PWC-8) and Thermocouple cable (THC-8) |
| Construction |
Heavy duty welded aluminum frame; air vent on bottom & side for cooling; top & bottom module
insertion guides. Thermocouple Connector (FCK-TC, 25 pin, male) &
Power Connector (FCK-PR, 25 pin, female) are mounted on the LHS of the
main frame. Input power cord grip is mounted on RHS of the main frame
(input power cord in not supplied). Completely self contained with no
external components required. PFS-812 Floor Stand can be used to mount the
main frame. It accepts all ITC temperature control modules. |
| Compatibility |
Compatible with industry standard
control modules and main frames |
| Dimensions & Weight (without modules
& cables) |
9" (H) x 20.25" (W) x 11.5" (D); Approx. 15 lbs |
18" (H) x 20.25" (W) x 11.5" (D); Approx.
32 lbs |
18" (H) x 20.25" (W) x 11.5" (D); Approx.
32 lbs |
Top |